Leave Your Message

ARM5 series thermal magnetic type double-breaker mccb 200ka icu=ics Thermal ajustable type mccb 400VAC/415VAC/550VAC/ 690VAC/800VAC400A 630A 3/4 Poles

ARM5

ARM5 series thermal magnetic type double-breaker mccb 200ka icu=ics Thermal ajustable type mccb 400VAC/415VAC/550VAC/ 690VAC/800VAC400A 630A 3/4 Poles

Rated Current : 400A、500A、630A

Number Of Poles : 3P / 4P

Rated Working Voltage : 400V/690V

    MCCB Highlights

    The reasonable structure design of moving and fixed contacts makes the short circuit peak value and energy of this series of products I²t much smaller than expected

    fasdfp8ahgfh6ab

    Working principle: the current flows in from the fixed contact
    1, flows out from the fixed contact
    2, through the moving, fixed silver contact and the moving contact. The moving contact quickly disconnects under the action of strong electric repulsion force (Holm force and Lorentz force) to improve the breaking speed.

    Air blowing design: when the short circuit large current occur in the circuit, the gas producing parts will generate other gas under the high temperature of the arc, the air pressure in the contact unit box increases rapidly, and a high-speed air flow can be formed through the air outlet of the arc extinguishing chamber, which can effectively extinguish the arc.

    ARM5

    Main performance index of ARM5 series circuit breaker

    Model ARM5-630
    Rated current In (A) 400A/500A/630A
    Rated current of frame size Inm (A) 630A
    Usage category Category A
    Rated ultimate short-circuit breaking capacity level L M H
    Number of poles (P) 3P 4P 3P 4P 3P 4P
    Rated working voltage Ue (V) 400V/415V
    Rated ultimate short-circuit breaking capacity Icu (kA) 85kA 150kA 200kA
    Rated service short-circuit breaking capacity Ics (kA) 85kA 150kA 200kA
    Rated working voltage Ue (V) 550V/690V
    Rated ultimate short-circuit breaking capacity Icu (kA) 35kA 50kA 65kA
    Rated service short-circuit breaking capacity Ics (kA) 35kA 50kA 65kA
    Rated insulation voltage Ui (V) 1000V
    Rated impulse withstand voltage Uimp (V) 8kV
    Mechanical life (time) 7000
    Electrical life (time) 400ln
    1000
    Arcing distance (mm) 0
    Release type Thermomagnetic
    W*L*H (mm)654dc7e6j1 W 140 185 140 185 140 185
    L 123.5
    H 123.5

    Overall and installation dimensions of circuit breaker

    Circuit breaker 630 frame size installation safety interval

    ■ ARM5-630 front panel wiring (3P/4P)
    X-X, Y-Y are the center of three-pole circuit breaker


    Model H H1 H0
    B C D
    ARM5-630 123.5 167.1



    ARM5E-630 123.5 167.1



    ARM5EHU-630 123.5 167.1

    ARM5-600dxn

    MCCB Production Line Real Showing

    Leave Your Message