Air circuit breaker ARW1-6300 air Circuit Breaker drawer/fixed type Switch 400VAC/690VAC 6300A 3 poles 4 poles
ARW1 Kapaligiran ning pamangamit
I、Ing humidity ning makapadurut a angin -40P-+40P; ing average a ulaga ning 24h e ya lalagpus keng +35P, ing mas mababa nang limitasyun ning humidity ning makapadurut a angin -40^ (maliban keng espesyal a deklarasyon).
II、Ing katas ning pangkabilugan a uri e ya dapat lalagpus 2000m, maigit 2000m ing gamitan a maki mababang kapasidad, at ing uri ning plateau e ya dapat lalagpus 5000m.
III、King maximum a temperatura a +40P, ing relatibong humidity ning angin e ya dapat lalagpus king 50%, king mas mababang temperatura ing mas matas a relatibong humidity malyari yang paintulutan, alimbawa, 90% king 20P.
IV、Pollusyun a klase: Klasi 3
Ⅴ、Protection class: IP30
II、Ing katas ning pangkabilugan a uri e ya dapat lalagpus 2000m, maigit 2000m ing gamitan a maki mababang kapasidad, at ing uri ning plateau e ya dapat lalagpus 5000m.
III、King maximum a temperatura a +40P, ing relatibong humidity ning angin e ya dapat lalagpus king 50%, king mas mababang temperatura ing mas matas a relatibong humidity malyari yang paintulutan, alimbawa, 90% king 20P.
IV、Pollusyun a klase: Klasi 3
Ⅴ、Protection class: IP30
ARW1

Main performance index ning ARW1 series circuit breaker
| Maikabilu | ARW1-6300 | ||
| Rated current In (A) 40°C | 4000A, 5000A, 6300A | ||
Rated current ning frame sizeInm (A) | 6300A | ||
| Kategorya ning pamangamit | Category B | ||
| Bilang da reng poste (P) | 3P | 4P | |
| Rated working voltage Ue (V) | AC400V | ||
| Rated ultimate short-circuit breaking capacity Icu (kA) | 120KA | ||
| Rated service short-circuit breaking capacity Ics (kA) | 100KA | ||
| Rated short-time standstand current Icw (kA/s) | 100KA/s | ||
| Rated working voltage Ue (V) | AC690V | ||
| Rated ultimate short-circuit breaking capacity Icu (kA) | 85KA | ||
| Rated service short-circuit breaking capacity Ics (kA) | 85KA | ||
| Rated short-time standstand current Icw (kA/s) | 85KA/s | ||
| Rated insulation voltage Ui (V) | 1000V | ||
| Rated impulse standing voltage Uimp (V) | 12kv | ||
| Arcing distance (mm) | 0 | ||
| Paralan ning pamag-install | Draw-out type, fixed type | ||
| Electromagnetic compatibility (EMC) | Kapaligiran A | ||
| Isolation applicability | Pamag-isolate | ||
W*L*H (mm)
| 3P | 845×432×400 | / |
| 4P | 960×432×400 | / | |
| pakete 3p | / | ||
| pakete 4p | / | ||
| Timbang 3p | 23300G | 7200G | |
| Timbang 4p | 25000G | 8500G | |
Ing kabilugan ampo ing sukad ning pamag-install ning circuit breaker
ARW1-3200 fixed circuit breaker overall ampo installation dimension

ARW1-3200 draw-out circuit breaker kabilugan ampo sukad ning pamag-install

Kagamitan ning Air circuit breaker
010203040506

Deng kekang solusyun para keng pamamye kuryenti
Electronic MCCB
400V/690V ACB
Thermal magnetic MCCB