Leave Your Message
ARXM3 Series thermal magnetic type mccb 400V/690V 63A 100A 125A 3/4 Poles
ARXM3

ARXM3 Series thermal magnetic type mccb 400V/690V 63A 100A 125A 3/4 Poles

Rated Current : 16A、20A、25A、32A、40A、45A、50A、55A、60A、63A、65A、70A、80A、85A、90A、95A、100A、125A

Number Of Poles : 3P / 4P

Rated Working Voltage : 400V/690V

    MCCB Highlights

    The molded case circuit breaker has overload, short circuit and undervoltage protection functions, and can protect lines and power equipment from damage.

    1. According to the rated ultimate short-circuit breaking capacity, the mccbs are classified into four types: C (economic type), L (standard type), M (medium breaking type) and H (high breaking type).

    2. ARM3 accessories are modularized, safe and reliable, with small volume, high breaking capacity, short flashover, high vibration resistance, etc

    3. The moulded case circuit breaker has passed the test requirements of GB/T2423.and IEC60947 standard, and can withstand the influence of humid air, salt mist, oil mist and mold

    4. The neutral pole type of ARXM3-125~630 mccb is A/B circuit breaker when it is of 4 poles specification, which can have a unique function of "overload alarm without tripping" to ensure the continuity of power supply and meet the requirements of Article 6.3.6 of GB50054.

    5. It is required to withstand mechanical vibration with frequency of 2Hz~13.2Hz, displacement of ± 1mm, frequency of 13.2Hz~100Hz and acceleration of ± 0.7g;

    ARXM3

    Main performance index of ARXM3 series circuit breaker

    Model ARXM3-125
    Rated current In (A) 16A/20A/25A/32A/40A/50A/63A/80A/100A/125A
    Rated current of frame size Inm (A) 125A
    Usage category Category A
    Rated ultimate short-circuit breaking capacity level C S L M H
    Number of poles (P) 3P 4P 3P 3P 4P 3P 4P 4P 4P
    Rated working voltage Ue (V) 400V
    Rated ultimate short-circuit breaking capacity Icu (kA) 35kA 25kA 50kA 70kA 100kA
    Rated service short-circuit breaking capacity Ics (kA) 22kA 18kA 35kA 50kA 70kA
    Rated working voltage Ue (V) 690V
    Rated ultimate short-circuit breaking capacity Icu (kA) 10kA 20kA 20kA 20kA 20kA
    Rated service short-circuit breaking capacity Ics (kA) 6kA 10kA 10kA 10kA 10kA
    Rated insulation voltage Ui (V) 1000V
    Rated impulse withstand voltage Uimp (V) 8kV
    Mechanical life (time) 8500
    Electrical life (time) 1500
    Arcing distance (mm) ≯50
    W*L*H (mm)w*l*h 3P 75*132.5*65 92*150*70 92*150*87
    4P 100*132.5*65 / 122*150*87
    package 3p 110*170*110 110*170*110 108*166*128
    package 4p 130*175*130 / 130*173*128
    weight 3P 1024g 1104g 1603g
    weight 4P 1334g / 2000g

    Overall and installation dimensions of circuit breaker

    ■ ARXM3-125C, front panel wiring (3P, 4P)
    X-X, Y-Y are the center of three-pole circuit breaker

    front panel wiring

    ■ ARM3-125S, ARM3-125 (L,M,H), ARXM3-125S , ARM3E-125(M,H)plug-in rear panel wiring(3P, 4P)
    X-X, Y-Y are the centers of three-pole circuit breaker

    Plug-in type mounting plate size

    Plug-in type mounting plate size

    Circuit breaker 125 frame size installation safety interval

    ■ Front panel wiring (3P, 4P)
    X-X, Y-Y are the center of three-pole circuit breaker

     
    Model H H H1 A B C D
    ARM3-125(C/S/L) 22.5 0 106~110 35 20 32.5 57
    ARM3-125(M/H) 22.5 87 106~110 35 20 32.5 57
    ARXM3-125S 22.5 70 106~110 35 20 32.5 57
    ARXM3-125(L/M/H) 22.5 87 106~110 35 20 32.5 57

    Model H0 H H1 A B C D
    ARM3E-125(M/H) 28.5 2 106~110 16 22 28 42
    ARM3ER-160(M/H) 28.5 92 106~110 16 22 26.5 42
    ARM3L-125(M/H) 28.5 93 106~110 16 22 28 50
    ARXM3R-160(S/L/M) 22.5 70 106~110 85 20 32.5 57

    Front panel wiringFront panel wiring

    ■ Rear panel wiring (3P, 4P)
    X-X, Y-Y are the center of three-pole circuit breaker

    Rear panel wiring

    ■ Plug-in rear panel wiring (3P, 4P)
    X-X, Y-Y are the centers of three-pole circuit breake

    Model A B
    ARXM3-125 56 91
    ARM3E-125 50 85
    Plug-in rear panel wiring

    MCCB Production Line Real Showing